01Available range

Unit type
SR Condensing unit
SP Heat pump condensing unit
(reversible on the refrigerant side)

Version
VB Base version
VD Desuperheater version
VR Total recovery version

Acoustic setting up
AB Base setting up
AS Low noise setting up
AX eXtra low noise setting up

Source temperature level
M Medium temperature level
A High temperature level

Unit description

This series of condensing units satisfies the cooling and heating requirements of residential plants of medium size.

All the units are suitable for outdoor instal¬lation and can be connected to a remote heat exchanger properly designed in or¬der to transfer to the plant all the cooling (and heating for reversible units) power generated.

The refrigerant circuit, contained in a compartment protected from the air flow to simplify the maintenance operations, is equipped with scroll compressors mounted on damper supports, thermosta¬tic expansion valve (only for SP), reverse cycle valve, axial fans with safety protection grilles, finned coil made of copper pipes and aluminium louvered fins with subcooling section. The circuit is protec¬ted by a safety gas valve, high and low pressure switches. All the units can be equipped with variable speed fans con¬trol that allows the units to operate with low outdoor temperatures in cooling and high outdoor temperature in heating and permits to reduce noise emissions in such operating conditions. The low noi¬se acoustic setting up (AS) is obtained, starting from the base setting up (AB), reducing the rotational speed of the fans and mounting sound jackets on the com¬pressors and the technical compartment is clad with soundproofing material of su¬itable thickness.

The eXtra low noise acoustic setting up (AX) is obtained, starting from the low noise setting up (AS), further reducing the rotational speed of the fans and using fin¬ned coil with bigger surface.

All the units are supplied with a manage¬ment and control electrical panel contai¬ning general switch, phase presence and correct sequence controller, microproces¬sor controller with display and all the other electrical components with IP54 minimum protection degree.

All the units are accurately built and indivi¬dually tested in the factory.

All the units are supplied with refrigerant charge inside. Only electric and refrige¬rant connections (between condensing unit and remote heat exchanger) are re¬quired for installation.

Options
Compressor starting
standard (contactors)
soft starter
Fans control
on-off control
modulating control
(condensation / eva¬poration control)
Compressor power factor correction
Electrical load protection
fuses
thermal magnetic circuit breakers
Coil condensate tray

Accessories
Rubber vibration dampers
Spring vibration dampers
Coil protection grilles
Remote control
Modbus serial interface on RS485
Programmer clock
Phase sequence and voltage controller
Low temperature kit (standard for SP)
High and low pressure gauges
High temperature thermostat
Coil shut off valves
Outdoor air sensor
Remote plate heat exchanger
Liquid line